DPO3012 / 100MHz, 2ch, 2.5GS/s, 요약정보 및 구매

제조사 Tektronix
브랜드 Tektronix
판매가격 전화문의
배송비결제 주문시 결제
  • 카탈로그
  • 메뉴얼
  • 프로그램
  • 드라이버
  • 데이터시트

상품 정보

상품 상세설명

item_point.gifCharacteristics/Specs
VerticalSystem
DPO3012
DPO3014
DPO3032
DPO3034
DPO3052
DPO3054
Input Channels
2
4
2
4
2
4
Analog Bandwidth (-3dB)
100 MHz
100 MHz
300 MHz
300 MHz
500 MHz
500 MHz
Calculated Rise Time
5 mV/div (typical)
3.5ns
3.5ns
1.17 ns
1.17 ns
700 ps
700 ps
Hardware Bandwidth Limits
20 MHz or 150 MHz
Input Coupling
AC, DC, GND
Input Impedance
1 MΩ ±1%, 75 Ω ±1%, 50 Ω ±1%
Input Sensitivity Range, 1MΩ
1 mV/div to 10 V/div
Input Sensitivity Range, 75Ω,50Ω
1 mV/div to 1 V/div
Vertical Resolution
8 bits (11 bits with Hi-Res)
Max Input Voltage,1MΩ
300 VRMS with peaks ≤±450 V
Max Input Voltage, 75Ω,50 Ω
5 VRMS with peaks ≤±20 V
DC Gain Accuracy
±1.5% with offset set to 0 V
OffsetRange
1MΩ
50Ω, 75Ω
1 mV/div to 99.5mV/div
±1V
±1V
100mV/div to 995mV/div
±10V
±5V
1 V/div
±100V
±5V
1.01 V/div to 10 V/div
±100V
NA
Channel-to-Channel Isolation
(Any Two Channels at Equal Vertical Scale)
≥ 100:1 at ≤100 MHz and ≥ 30:1 at > 100MHz up to the rated BW
Horizontal System
All DPO3000 Models
Maximum Sample Rate (all channels)
2.5 GS/s
Maximum Record Length (all channels)
5 M points
Maximum Duration of Time Captured at Highest Sample Rate (all channels)
2 ms
Time base Range (S/div)
1 ns to 1000 s
Time base Delay Time Range
- 10 divisions to 5000 s
Channel-to-Channel Deskew Range
±100 ns
Timebase Accuracy
±10 ppm over any ≥ 1 ms interval
Trigger System
Main Trigger Modes
Auto, Normal, and Single
Trigger Coupling
DC, AC, HF reject (attenuates>50 kHz), LF reject (attenuates <50 kHz), noise reject (reduces sensitivity)
Trigger Holdoff Range
20 ns to 8 s
Sensitivity
Internal DC Coupled
0.4 div DC to 50 MHz, increasing to 1 div at rated bandwidth
External (Auxiliary Input)
200mV from DC to 50MHz increasing to 500mV at 250MHz
Trigger Level Range
Any Channel
±8 divisions from center of screen
External (auxiliary input)
±8V
Acquisition Modes
Sample
Acquire sampled values
Peak Detect
Captures narrow glitches at all real-time sampling rates
Averaging
From 2 to 512 waveforms included in average
Envelope
Min-max envelope reflecting Peak Detect data over multiple acquisitions
Hi-Res
Real-time boxcar averaging reduces random noise and increases resolution
Roll
Scrolls waveforms right to left across the screen at sweep speeds slower than or equal to 40ms/div
Trigger Modes
Edge
Positive or negative slope on any channel or front panel auxiliary input. Coupling includes DC, AC, HF reject, LF reject and noise reject
Pulse Width
Trigger on width of positive or negative pulse that are >, <, = or ≠ a specified period of time
Runt
Trigger on a pulse that crosses one threshold but fails to cross a second threshold before crossing the first again
Logic
Trigger when any logical pattern of channels goes false or stays true for specified period of time. Any input can be used as a clock to look for the pattern on a clock edge. Pattern (AND, OR, NAND, NOR) specified for four input channels defined as High, Low or Don’t Care.
Setup and Hold
Trigger on violations of both setup time and hold time between clock and data present on any two input channels
Rise/Fall Time
Trigger on pulse edge rates that are faster or slower than specified. Slope may be positive, negative or either.
Video
Trigger on all lines, odd, even or all fields on NTSC, PAL and SECAM video signals
Extended Video (optional)
Trigger on 480p/60, 576p/50, 720p/30, 720p/50, 720p/60, 875i/60, 1080i/50, 1080i/60, 1080p/24, 1080p/24sF, 1080p/25, 1080p/30, 1080p/50, 1080p/60 and custom bi-level and tri-level sync video standards
I2C (optional)
Trigger on Start, Repeated Start, Stop, Missing ACK, Address (7 or 10 bit), Data or Address & Data on I2C buses up to 3.4 Mb/s
SPI (optional)
Trigger on SS, MOSI, MISO or MOSI & MISO on SPI buses up to 10.0 Mb/s
CAN (optional)
Trigger on Start of Frame, Frame Type (data, remote, error, overload), Identifier (standard or extended), Data, Identifier and Data, End of Frame, Missing ACK, or Bit Stuffing Error on CAN signals up to 1 Mb/s. Data can be further specified to trigger on ≤, <, =, >, ≥ or ≠ a specific data value. User-adjustable sample point is set to 50% by default.
LIN (optional)
Trigger on Sync, Identifier, Data, Id & Data, Wakeup Frame, Sleep Frame, Error up to 100 kb/s
RS-232/422/485/UART (optional)
Trigger on Tx Start Bit, Rx Start Bit, Tx End of Packet, Rx End of Packet, Tx Data, Rx Data, Tx Parity Error, and Rx Parity Error
Trigger Delay by Time
4 ns to 8 s
Trigger Delay by Events
1 to 9,999,999 events
Waveform Measurements
Cursors
Waveform and Screen
Automatic Measurements
29, of which up to four can be displayed on screen at any one time.
Measurements include: Period, Frequency, Delay, Rise Time, Fall Time, Positive Duty Cycle, Negative Duty Cycle, Positive Pulse Width, Negative Pulse Width, Burst Width, Phase, Positive Overshoot, Negative Overshoot, Peak to Peak, Amplitude, High, Low, Max, Min, Mean, Cycle Mean, RMS, Cycle RMS, Rising Edge Count, Falling Edge Count, Positive Pulse Count, Negative Pulse Count, Area and Cycle Area.
Measurement Statistics
Mean, Min, Max, Standard Deviation
Reference Levels
User-definable reference levels for automatic measurements can be specified in either percent or units
Gating
Isolate the specific occurrence within an acquisition to take measurements on, using either the screen, or waveform cursors
Waveform Math
Arithmetic
Add, subtract, multiply, and divide waveforms
Math Functions
Integrate, Differentiate, FFT
FFT
Spectral magnitude. Set FFT Vertical Scale to Linear RMS or dBV RMS, and FFT Window to Rectangular, Hamming, Hanning, or Blackman-Harris
Advanced Math
Define extensive algebraic expressions including waveforms, math functions, scalars, up to two user adjustable variables and results of parametric measurements e.g.,(Intg(Ch1–Mean(Ch1)) x 1.414 x VAR1)
Software
NI LabVIEW SignalExpressTM Tektronix Edition
A fully interactive measurement software environment optimized for the DPO3000 Series, enables you to instantly acquire, generate, analyze, compare, import and save measurement data and signals using an intuitive drag-and-drop user interface that does not require any programming.
Standard DPO3000 Series support for acquiring, controlling, viewing and exporting your live signal data. A 30-day trial period of the Full Version provides additional signal processing, advanced analysis, mixed signal, sweeping, limit testing and user-defined step capabilities. Order SIGEXPTE for permanent Full Version capability.
OpenChoice®Desktop
Enables fast and easy communication between a Windows PC and the DPO3000 Series, via USB or LAN. Transfer and save settings, waveforms, measurements and screen images.
IVI Driver
Provides a standard instrument programming interface for common applications such as LabVIEW, LabWindows/CVI, Microsoft .NET and MATLAB
Display Characteristics
Display Type
9in. (228.6mm) wide format liquid crystal TFT color display
Display Resolution
800 horizontal x 480 vertical pixels (WVGA)
Waveform Styles
Vectors, Dots, Variable Persistence, Infinite Persistence
Graticules
Full, Grid, Cross Hair, Frame, IRE and mV
Format
YT and XY
Waveform Capture Rate
Up to 50,000 wfm/s
Input/Output Ports
USB 2.0 High Speed Host Port
Supports USB mass storage devices and printers. One port available on rear-panel and one on front-panel.
USB 2.0 High Speed Device Port
Rear panel connector allows for control of oscilloscope via USBTMC or GPIB with a TEK-USB-488
LAN Port
RJ-45 connector, supports10/100Base-T
Video Out Port
DB-15 female connector, connect to show the oscilloscope display on an external monitor or projector
Auxiliary Input
Front panel BNC connector. Input Impedance 1MΩ. Max input 300VRMS Cat II with peaks ≤±450V
Probe Compensator Output
Front panel pins. Amplitude 2.5V. Frequency 1kHz.
Trigger Out
Rear-panel BNC connector, provides a positive polarity pulse when the oscilloscope triggers
Kensington Lock
Rear-panel security slot connects to standard Kensington lock
Power Source
Power Source Voltage
85 to 265V ±10%
Power Source Frequency
45 to 440Hz (85 to 265V)
Power Consumption
120W maximum
Optional TekVPI® Power Supply
Output Voltage – 12V; Output Current – 5A; Power Consumption – 60W
Physical Characteristics
Dimensions
mm
in.
Height
203.2
8
Width
416.6
16.4
Depth
137.2
5.4
Weight
kg
lbs.
Net
4.17
9.2
Shipping
8.62
19
Rackmount Configuration
5U
Cooling Clearance
2in.(51mm) required on left side and rear of instrument
General Characteristics
Environmental
Temperature
Operating
0ºC to +50ºC
Non-operating
–40ºC to +71ºC
Humidity
Operating
High: 30ºC to 50ºC,5% to 45% Relative Humidity
Low: 0ºC to 30ºC,5% to 95% Relative Humidity
Non-operating
High: 30ºC to 50ºC,5% to 45% Relative Humidity
Low: 0ºC to 30ºC,5% to 95% Relative Humidity
Altitude
Operating
3,000 meters (9,843 feet)
Non-operating
12,000 meters (39,370 feet)
Random Vibration
Operating
0.31 GRMS from 5 to 500Hz, 10 minutes each axis, 3 axes, 30 minutes total
Non-operating
2.46 GRMS from 5 to 500Hz, 10 minutes each axis, 3 axes, 30 minutes total
Regulatory
Electromagnetic Compatibility
89/336/EEC
Safety
UL61010-1,Second Edition; CAN/CSA C22.2 No. 1010.1 1992, EN61010-1:2001; IEC 61010-1:2001

ordering_long_title3.gif

Digital Oscilloscope
item_point.gifOrdering Information
DPO3000 Series
Product
DPO3012
100 MHz, 2.5 GS/s, 5M record length, 2-channel digital phosphor oscilloscope
DPO3014
100 MHz, 2.5 GS/s, 5M record length, 4-channel digital phosphor oscilloscope
DPO3032
300 MHz, 2.5 GS/s, 5M record length, 2-channel digital phosphor oscilloscope
DPO3034
300 MHz, 2.5 GS/s, 5M record length, 4-channel digital phosphor oscilloscope
DPO3052
500 MHz, 2.5 GS/s, 5M record length, 2-channel digital phosphor oscilloscope
DPO3054
500 MHz, 2.5 GS/s, 5M record length, 4-channel digital phosphor oscilloscope
Included: All models include: One P6139A 500MHz, 10x Passive Probe per Channel, Front Cover (200-5052-xx), User Manual, Documentation CD (063-4104-xx), OpenChoice® Desktop Software, NILabVIEW SignalExpress™ Tektronix Edition LESoftware, Calibration Certificate Documenting Traceability to National Metrology Institute(s) and ISO9001 Quality System Registration, Power Cord, Accessory Pouch (016-2008-xx), Three-year Warranty. Please specify power plug and manual language version when ordering.
Application Modules
DPO3AUTO
Automotive Serial Triggering and Analysis Module. Enables triggering on packet level information on CAN bus and LIN bus as well as analytical tools such as digital views of the signal, bus views, packet decoding, search tools and packet decode tables with timestamp information.
DPO3EMBD
Embedded Serial Triggering and Analysis Module. Enables triggering on packet level information on I2C and SPI buses as well as analytical tools such as digital views of the signal, bus views, packet decoding, search tools an