Electrical specifications |
Current measurement dc and ac 10 Hz to 100 Hz | Range : 40 A | Resolution: 10 mA Accuracy, A: 1.5 % rdg + 15 digits Trigger Level for Inrush: 0.50 A Trigger Level for Hz Filter OFF: 2.50 A Trigger Level for Hz Filter ON: 0.50 A | Range : 400 A | Resolution: 100 mA Accuracy, A: 1.5 % rdg + 5 digits Trigger Level for Inrush: 5.0 A Trigger Level for Hz Filter OFF: 2.5 A Trigger Level for Hz Filter ON: 2.5 A | Range : 2000 A; 1400 ac rms | Resolution: 1 A Accuracy, A: 1.5 % rdg + 5 digits Trigger Level for Inrush: 5 A Trigger Level for Hz Filter OFF: 8 A Trigger Level for Hz Filter ON: 8 A |
|
Crest Factor (50/60 Hz) | Range : 40 A | Crest Factor* : 2 @ 33 A, 2.4 @ 27 A | Range : 400 A | Crest Factor* : 2 @ 330 A, 2.4 @ 270 A | Range : 2000 A; 1400 ac rms | Crest Factor* : 2 @ 1000 A, 2.4 @ 833 A |
|
Current measurement ac 100.1 Hz to 1 kHz | Range : 40 A | Resolution: 10 mA Accuracy > 10 A : 3.5 % rdg + 15 digits Trigger Level for Inrush: 0.50 A Trigger Level for Hz Filter OFF : 2.50 A Trigger Level for Hz Filter ON : 0.50 A | Range : 400 A | Resolution: 100 mA Accuracy > 10 A : 3.5 % rdg + 5 digits Trigger Level for Inrush: 5.0 A Trigger Level for Hz Filter OFF : 2.5 A Trigger Level for Hz Filter ON : 2.5 A | Range : 2000 A; 1400 ac rms | Resolution: 1 A Accuracy > 10 A : 3.5 % rdg + 5 digits Trigger Level for Inrush: 5 A Trigger Level for Hz Filter OFF : 8 A Trigger Level for Hz Filter ON : 8 A |
|
Voltage measurement (355 only) dc and ac 10 Hz to 100 Hz (600 V and 1000 V ranges have 10 % over range to 660 V and 1100 V respectively.) | Range : 4 V | Resolution: 1 mV Accuracy: 1 % rdg + 10 digits Trigger Level for Hz Filter OFF: 0.050 V Trigger Level for Hz Filter ON: 0.050 V | Range : 40 V | Resolution: 10 mV Accuracy: 1 % rdg + 5 digits Trigger Level for Hz Filter OFF: 0.25 V Trigger Level for Hz Filter ON: 0.25 V | Range : 400 V | Resolution: 100 mV Accuracy: 1 % rdg + 5 digits Trigger Level for Hz Filter OFF: 6 V Trigger Level for Hz Filter ON: 6 V | Range : 600 V ac rms | Resolution: 1 V Accuracy: 1 % rdg + 5 digits Trigger Level for Hz Filter OFF: 6 V Trigger Level for Hz Filter ON: 6 V | Range : 1000 V dc | Resolution: 1 V Accuracy: 1 % rdg + 5 digits |
|
Voltage measurement (355 only) ac 100.1 Hz to 1 kHz (600 V and 1000 V ranges have 10 % over range to 660 V and 1100 V respectively.) | Range: 4 V | Resolution: 1 mV Accuracy: 3 % rdg + 10 digits Trigger Level for Hz Filter OFF: 0.050 V Trigger Level for Hz Filter ON: 0.050 V | Range: 40 V | Resolution: 10 mV Accuracy: 3 % rdg + 5 digits Trigger Level for Hz Filter OFF: 0.25 V Trigger Level for Hz Filter ON: 0.25 V | Range: 400 V | Resolution: 100 mV Accuracy: 3 % rdg + 5 digits Trigger Level for Hz Filter OFF: 6 V Trigger Level for Hz Filter ON: 6 V | Range: 600 V ac rms | Resolution: 1 V Accuracy: 3 % rdg + 5 digits Trigger Level for Hz Filter OFF: 6 V Trigger Level for Hz Filter ON: 6 V |
|
Ohms measurement (355 only) | Range: 400 Ω | Resolution: 0.1 Ω Accuracy: 1.5 % + 5 digits | Range: 4 kΩ | Resolution: 1 Ω Accuracy: 1.5 % + 5 digits | Range: 40 kΩ | Resolution: 10 Ω Accuracy: 1.5 % + 5 digits | Range: 400 kΩ | Resolution: 100 Ω Accuracy: 1.5 % + 5 digits |
|
Continuity beeper (355 only) | | On at ≤ 30 Ω | | Off at ≥ 100 Ω |
|
Frequency measurement | Measurement range | 5.0 Hz to 1 kHz | Resolution | 0.1 Hz (15 Hz to 399.9 Hz); 1 Hz (400 Hz to 1 kHz) | Accuracy – 5.0 Hz to 100 Hz | 0.2 % + 2 counts | Accuracy – 100.1 Hz to 1 kHz | 0.5 % + 5 counts | Trigger level | Refer to current and voltage tables |
|